American Wire Group - Item # XHHW-C4/0, XHHW-2 XLP Copper Conductor<br>600 Volts, 90<sup>o</sup>C Wet or Dry
 Search Catalog
      GO   
 All Categories    XHHW-2 XLP Copper Conductor
600 Volts, 90oC Wet or Dry
AWG CODE NAME FINDER
Enter code name in the search field to the left for specific product information
All Categories > Copper Building Wire > THHN/THWN-2 Copper Conductor
600 Volts, 90oC Dry or 75oC Wet
 > IMSA 50-2
Loop Detector Lead-In Wire
 > 
Single Conductor
600 V Secondary Type UD Cable
Aluminum Conductor
 > Mobile Home Feeder - Aluminum Conductor > Covered Line Wire ACSR
Aluminum Conductor
 > Type TFFN/TFN Copper Conductor
600 Volts 90oC Dry Locations
 > Ground Rod Accessories - Driving Studs > XHHW-2 XLP Copper Conductor
600 Volts, 90oC Wet or Dry
 > Item # XHHW-C4/0 
 
    Download PDF Download PDF     Email Email This Page     Save To Favorites Save To Favorites
Request Information

Item # XHHW-C4/0 XHHW-2 XLP Copper Conductor
600 Volts, 90oC Wet or Dry



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

XHHW-2 Copper

larger image
Applications
Single Conductor Crosslinked polyethylene (XLP or XLPE) Type XHHW-2, intended for use at 600 volts or less. It is approved for general purpose lighting and power applications at a maximum continuous operating temperature of 90°C in wet or dry locations. VW-1 available where required.

Construction
Single copper conductors, solid or stranded annealed or hard uncoated copper per UL83 and ASTM requirements. Insulates with XLP as specified and applied tightly to the conductor in a concentric manner. The mimimum at any point shall not be less than 90% of the specified average thickness in compliance with UL 44. Identified by surface marking indicating the manufacturer, conductor size, voltage rating, UL symbol, and type designation. Continuously spark tested at 7500 Volts DC and pass the 4 hour cold bend test of -25oC. Other electrical and mechanical tests shall be in accordance with UL 44 and UL 1581.

Standards
  • ASTM B-1, B-3, and B-8 for copper conductors.
  • ICEA S-66-524/NEMA WC7 Cross Linked Polyethylene Insulated Wire & Cable, UL 44 for Thermoset Insulated Wires & Cables, Fed Spec J-C-30B.





  • Specifications

    Size AWG or MCM

    4/0

    Number
    of
    Strands

    19

    Insulation Thickness
    (mls)

    55

    Approx O.D.
    (Inches)

    0.645

    Copper Weight
    (lbs. per MFT)

    653.3

    Shipping Weight
    (lbs. per MFT)

    702

    Ampacity 90°C Dry

    260


    Request Information